41913-000 | Quote |
---|
Ideal training tool for hands-on workshop of vertebroplasty / The phantom has two types of interchangeable and replaceable inserts with radio-opaque lumbar spine
- lumbar
- fluoroscopy
- vertebroplasty
PH-51
41913-000 | Quote |
---|
Ideal training tool for hands-on workshop of vertebroplasty / The phantom has two types of interchangeable and replaceable inserts with radio-opaque lumbar spine
Features | 1. Two types of replaceable training block: vertebroplasty block and anesthesia block 2. Lumbar spine L2-L5 can be visualized under X-ray. 3. True-to-life sensation when penetrating tissue and bones. |
---|---|
Set includes | 1 lumbar torso 1 vertebroplasty block 1 anesthesia block 1 skin cover 1 syringe 1 irrigation bag 1 storage case manual |
Size (approx.) | W33 x D21 x H30 cm / W13 x D8.2 x H11.8 in |
Packing size (approx.) | W52 x D44 x H30 cm / W20.5 x D17.3 x H11.8 in |
Weight (approx.) | 1.5kg / 3.3lb (Assessment unit) |
Materials | Soft tissue: urethane based resin (specific gravity: 1.06) / Synthetic bone: epoxy resin (specific gravity: 1.31) |
Replacement parts | 41913-000-01 anesthesia block for PH-51 / 41913-000-02 vertebroplasty block for PH-51 / 11348-150 Replacement skin cover for M43B |
Optional parts | 11348-090 1 LP block (normal CSF) 11348-110 1 LP block (obesity CSF) 11348-120 1 LP block (senior CSF) 11348-130 1 LP block (senior obesity CSF) 11348-140 1 epidural block 11348-150 1 lumbar region skin cover |
Related products |
M43B Lumbar Puncture Simulator II
MW3 Epidural Anesthesia Simulator M43E Ultrasound Compatible Lumbar Puncture/ Epidural Simulator |
Production & Development Supervision | Dr. David Wilson MBBS, BSc, MFSEM, FRCP, FRCR, Consultant Radiologist St Luke's Hospital Oxford, Senior Clinical Lecturer University of Oxford |
ANATOMY | Lumbar spine (L2-L5) / Spinal canal / Epidural space (anesthesia block only) |
Application | Recognition of fluoroscopic anatomy and landmarks / Vertebroplasty / Fluoroscopy guided epidural anesthesia: needle placement in facet joint injection, root block and discogram. |
Doctor's Voice | "I have tested the final product with various different manufacturing kits and would have no hesitation in recommending these phantoms to clinicians who wish to teach any of the technical vertebroplasty procedures." / DR DAVID J WILSON MBBS BSc MFSEM FRCP FRCR / CONSULTANT MUSCULOSKELETAL INTERVENTIONAL RADIOLOGIST |
Notes | Recommended devices: Epidural needle: 18G / Spinal needle: 21G |
Update | July 14, 2020 |